PNI Sensor Corporation Doc 1017252 r02
RM3100 Evaluation Board User Manual Page 30 of 33
Once the measurement sequence is completed on all desired axes, the DRDY pin
is set HIGH and the MISO pin goes low, indicating data is read. The MagI2C is
placed in Idle Mode.
When the host is ready to read the measured values, set SSN to LOW. If SSN
already is LOW, then toggle SSN from LOW to HIGH to LOW.
Assuming the X axis was one of the axes to be measured, send the MX2 Read
address, 0xA4, to begin reading the Measurement Results registers. The
measurement readings will now clock out, with the 3 bytes of X-axis data
presented first, then Y-axis data, then Z-axis data. The first nine (9) bytes
represent a complete 3-axis measurement.
Return SSN to HIGH to free up the host to communicate with other devices and
5.8 Examples using the I
2
C Interface
5.8.1 Set the Cycle Count Registers
A sample command sequence is provided below which sets the cycle count value to 100
D
(64
H
) for all 3 axes. This is for illustrative purposes and the value could be different
and/or the number of axes to be addressed could be different. Note only the initial Cycle
Count register address needs to be sent, as the RM3100 Evaluation Board automatically
increments to the next register.
RM3100 Eval Board