PNI Sensor Corporation Doc #1018049 R03
SENtral Technical Data Sheet Page 27
5.6 Troubleshooting
This section provides guidance in troubleshooting SENtral, and is divided into hardware-
related and software-related errors.
5.6.1 Hardware-Related Error Conditions
Possible indications of a hardware-related problem are given below in Table 5-9.
Table 5-9: Hardware-Related Error Indications
[0] 1 = CPURest. SENtral Configuration
File needs uploading. See Section 5.1.
[2] 1 = EEUploadError. Issue with
uploading from the dedicated EEPROM.
See Section 5.1.
In the event of such errors, SENtral will enter Standby State, shut down the sensors, and
generate an interrupt to the host. Possible reasons for hardware-related errors include
problems with an external EEPROM upload, power transients detected by power
management, and errors in software detected by Watchdog. Often the error can be
cleared by sending the ResetReq command and reloading the Configuration File.
5.6.2 Software-Related Error Conditions
Possible indications of software-related errors are given below in Table 5-10:
Table 5-10: Software-Related Error Indications
Non-zero value indicates sensor-related error. Check
sensors by communicating in Pass-Through State.
See Table 5-11
[3] 1 = Idle. SENtral in Initialized or Unprogrammed
State.
Non-zero value indicated an error. See Table 5-12.
Unexpected Configuration File revision level.